Products / Bioscience Solutions / Optogenetics Starter Kits Optogenetics Starter Kits
Optogenetics Starter Kits
Price range: $2,219.00USD through $2,819.00USD
Mightex’s optogenetics starter kits are ready-to-use turn-key solution for ChR2 stimulation. Based on our high-power fiber-coupled LED’s and versatile LED controllers, the starter kits are specifically designed to provide the most cost-effective turn-key solutions for ChR2 stimulation. They feature super-high output power (up to 7.2mW with a 200µm fiber) and ultra-low power variation (<2%) during rotation.
Customize your product
- Overview
- Specifications
- Packing List
- LED Control Modules
- Fiber-Optic Components
Mightex’s optogenetics starter kits are ready-to-use turn-key solution for ChR2 stimulation, and they feature super-high output power (up to 7.2mW with a 200µm fiber) and ultra-low power variation (<2%) during rotation. The optogenetics starter kit is typically composed of the following items:
- A 470nm fiber-coupled LED source (P/N: BLS-FCS-0470-100);
- An LED controller module;
- A fiber-optic rotary joint with SMA connector on one end and ceramic ferrule on the other, or a fiber-optic patch cord with SMA connector on one end and ceramic ferrule on the other;
- Two (2) mating sleeve for ferrule or cannula; and
- Four (4) implantable fiber optic cannula (two 5mm in length and two 10mm in length).
Mightex’s optogenetics starter kits can be summarized in the chart below.

Starter Kits with BLS-3000-2 LED Controller
| Starter Kit P/N | OGK-0470-0200-37-250-BLS3000 | OGK-0470-0200-37-125-BLS3000 | OGK-0470-0200-37-250-BLS3000-RJ | OGK-0470-0200-37-125-BLS3000-RJ |
| Light Source | BLS-FCS-0470-100, 470nm fiber-coupled LED | |||
| LED Controller | BLS-3000-2 | |||
| Fiber Core Size | Φ 200 µm | |||
| Cannula Ferrule Size | Φ 2.5mm | Φ 1.25mm | Φ 2.5mm | Φ 1.25mm |
| Cannula Output Power1 | 7.2mW | 6.4mW | 4mW | 3.6mW |
| Patch Cable | Standard | Integrated Rotary Joint | ||
| Variation in Output Power During Rotation2 | N.A. (system does not include a rotary joint) | ±2% | ||
Starter Kits with BLS-SA02-US LED Controller
| Starter Kit P/N | OGK-0470-0200-37-250-BLSSA02 | OGK-0470-0200-37-125-BLSSA02 | OGK-0470-0200-37-250-BLSSA02-RJ | OGK-0470-0200-37-125-BLSSA02-RJ |
| Light Source | BLS-FCS-0470-100, 470nm fiber-coupled LED | |||
| LED Controller | BLS-SA02-US | |||
| Fiber Core Size | Φ 200 µm | |||
| Cannula Ferrule Size | Φ 2.5mm | Φ 1.25mm | Φ 2.5mm | Φ 1.25mm |
| Cannula Output Power1 | 7.2mW | 6.4mW | 4mW | 3.6mW |
| Patch Cable | Standard | Integrated Rotary Joint | ||
| Variation in Output Power During Rotation2 | N.A. (system does not include a rotary joint) | ±2% | ||
1. Output power measured at the cannula at maximum driving current. For BLS-SA02-US LED controller, maximum driving current using Intellipulsing;
2. Output power variation during rotation of the rotary joint.
Optogenetics Starter Kits Configuration Table and Components Packing List
| Starter Kit P/N | Fiber-Coupled LED (470nm) | LED Controller | Rotary Joint Patch Cord | Fiber Patch Cord | Mating Sleeve | Implantable Fiber Cannula |
| OGK-0470-0200-37-250-BLSSA02 | BLS-FCS-0470-100 | BLS-SA02-US | - | FPC-0200-37-01SMA-250C | ACC-FPC-SLV250 (x2) | CNL-0200-37-05-250C (x2) CNL-0200-37-10-250C (x2) |
| OGK-0470-0200-37-250-BLS3000 | BLS-FCS-0470-100 | BLS-3000-2 | - | FPC-0200-37-01SMA-250C | ACC-FPC-SLV250 (x2) | CNL-0200-37-05-250C (x2) CNL-0200-37-10-250C (x2) |
| OGK-0470-0200-37-125-BLSSA02 | BLS-FCS-0470-100 | BLS-SA02-US | - | FPC-0200-37-01SMA-125C | ACC-FPC-SLV125 (x2) | CNL-0200-37-05-125C (x2) CNL-0200-37-10-125C (x2) |
| OGK-0470-0200-37-125-BLS3000 | BLS-FCS-0470-100 | BLS-3000-2 | - | FPC-0200-37-01SMA-125C | ACC-FPC-SLV125 (x2) | CNL-0200-37-05-125C (x2) CNL-0200-37-10-125C (x2) |
| OGK-0470-0200-37-250-BLSSA02-RJ | BLS-FCS-0470-100 | BLS-SA02-US | FPC-RJ-0200-37-03SMA-250C | - | ACC-FPC-SLV250 (x2) | CNL-0200-37-05-250C (x2) CNL-0200-37-10-250C (x2) |
| OGK-0470-0200-37-250-BLS3000-RJ | BLS-FCS-0470-100 | BLS-3000-2 | FPC-RJ-0200-37-03SMA-250C | - | ACC-FPC-SLV250 (x2) | CNL-0200-37-05-250C (x2) CNL-0200-37-10-250C (x2) |
| OGK-0470-0200-37-125-BLSSA02-RJ | BLS-FCS-0470-100 | BLS-SA02-US | FPC-RJ-0200-37-03SMA-125C | - | ACC-FPC-SLV125 (x2) | CNL-0200-37-05-125C (x2) CNL-0200-37-10-125C (x2) |
| OGK-0470-0200-37-125-BLS3000-RJ | BLS-FCS-0470-100 | BLS-3000-2 | FPC-RJ-0200-37-03SMA-125C | - | ACC-FPC-SLV125 (x2) | CNL-0200-37-05-125C (x2) CNL-0200-37-10-125C (x2) |
![]() ![]() | Software/TTL The BLS-SA02/04-US controller features simple software GUI, a one-stop interface to operate the LED sources in constant intensity, pulse, or external TTL triggered mode. 20µs minimum pulse width and up to 25kHz modulation frequency and TTL triggered operation for fast switching between different LED wavelengths, making this option an ideal choice for working with electrophysiology rig. BLS-SA02/04-US is also ideal for synchronization of light pulse with camera by using TTL signal. more |
![]() ![]() | Manual/Analog The superfast BLS-1000-2 and BLS-3000-2 controllers feature a modulation frequency of up to 100kHz using external analog control. Researchers can take full potential of solid-state LED’s speed to meet all their need for superfast modulation of illumination. Output waveform can be completely arbitrary since it is driven by analog signal. Two precise manual control dials offer on the unit simple access to constant intensity. Switches on the front panel are used to conveniently select between manual and analog signal control. more |
Implantable fiber optic cannula
- CNL-0200-37-05-250C, Implantable fiber optic cannula, 2.5mm ceramic ferrule with 0.37NA, 200um core fiber, protrusion length 5mm;
- CNL-0200-37-05-125C, Implantable fiber optic cannula, 1.25mm ceramic ferrule with 0.37NA, 200um core fiber, protrusion length 5mm;
- CNL-0200-37-10-250C, Implantable fiber optic cannula, 2.5mm ceramic ferrule with 0.37NA, 200um core fiber, protrusion length 10mm; and
- CNL-0200-37-10-125C, Implantable fiber optic cannula, 1.25mm ceramic ferrule with 0.37NA, 200um core fiber, protrusion length 10mm.
- ACC-FPC-SLV250, Mating sleeve for 2.5mm ferrule or cannula;
- ACC-FPC-SLV125, Mating sleeve for 1.25mm ferrule or cannula.
- FPC-0200-37-01SMA-250C, Multimode Fiber Patchcord, 0.37 NA, 200μm Core, SMA on one end , 2.5mm ceramic ferrule on other end, 1 meter long;
- FPC-0200-37-01SMA-125C, Multimode Fiber Patchcord, 0.37 NA, 200μm Core, SMA on one end , 1.25mm ceramic ferrule on other end, 1 meter long.
Fiber-Optic Rotary Joints with Patch Cords
- FPC-RJ-0200-37-03SMA-250C, Rotary Joint Multimode Fiber Patchcord, 0.37 NA, 200μm Core, SMA on one end , 2.5mm ceramic ferrule on other end, 3 meters total;
- FPC-RJ-0200-37-03SMA-125C, Rotary Joint Multimode Fiber Patchcord, 0.37 NA, 200μm Core, SMA on one end , 1.25mm ceramic ferrule on other end, 3 meters total.
Product specifications are subject to change without prior notice. All prices are FCA California, unless otherwise stated. Please call/email for volume pricing.


